CeilAir CW series Instrukcja Operatora Strona 1

Przeglądaj online lub pobierz Instrukcja Operatora dla Klimatyzatory typu split CeilAir CW series. CeilAir CW series Operator`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - (©July, 2008)

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.

Strona 2 - OHS-040-G-FC

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.1.6 General DesignThe CeilAiR unit is hous

Strona 3 - TABLE OF CONTENTS

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.1.6.5 Optional Equipment1.6.5.1 Humidistat

Strona 4

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2.0 Installation2.1 Receiving the Equipm

Strona 5 - 1.0 Introduction

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-2CAUTION When moving the unit, it must b

Strona 6 - 1.4 Product Warranty

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-3NOTESATS supplied thermostats/controls

Strona 7

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-4horizontally for ease of making wire co

Strona 8 - 1.5 Safety

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-5CAUTION The probes must not touch the m

Strona 9

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-62.5.2 Ducted Systems (See Figure 3)The

Strona 10 - 1.6 General Design

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-7Clear all pipe connections of debris an

Strona 11 - CeilAiR

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-8Vertical runs are based on a total rise

Strona 12 - 2.0 Installation

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.MODEL NOMENCLATUREOHS-040-G-FCOHS = Overhe

Strona 13 - WARNING

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-92.6.3 Condensate Drain Line2.6.3.1 Gr

Strona 14

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-102.7 Utility Connections2.7.1 Main Po

Strona 15

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-11to the surface of the unit. If the fac

Strona 16

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-12Upon examination of the buck/boost tra

Strona 17 - 2.6 Piping Connections

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-132.7.2.1 A-Tech-1.1 Programmable Thermo

Strona 18

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-14A-Tech-1.2 Dip Switch SettingsOFF ON O

Strona 19

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-152.7.3 Optional EquipmentNOTEAll cust

Strona 20

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-162.7.3.3 Remote Water DetectorSpot Type

Strona 21

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-17SEE NOTE 3REMOTE TEMPERATURE SENSOR (O

Strona 22

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-183. OPTIONAL REMOTE MOUNTED DEVICES (WI

Strona 23

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.1.0 Introduction ...

Strona 24

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-192.7.6 Remote Shut DownNOTEAll wiring

Strona 25

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-20ture-measuring device being well insul

Strona 26 - 2.7.3 Optional Equipment

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-21CAUTION POE oil is used in systems wit

Strona 27

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-222.9.2 Head Pressure Controls-Air Coole

Strona 28

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.2-23This method of controlling head pressu

Strona 29

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.4. Loosen the set screw in the side of the

Strona 30

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.The normal control setting is 50-55 psig (

Strona 31

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.(SaturatedVapor)(SaturatedLiquid)R22 Refri

Strona 32

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.3.0 Start-Up / Commissioning3.1 Operatio

Strona 33 - Air Cooled Systems

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.3-23.3 Thermostat Programming3.3.1 A-Te

Strona 34

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.List of FiguresFigure 1 Typical Installati

Strona 35

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.Program ScheduleMorningDayEveningNightEven

Strona 36

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.3-43.3.1.5 Reviewing ScheduledTimes and Te

Strona 37 - R407C Refrigerant

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.3.3.2 A-Tech-1.2 (See Figure 15)The A-Te

Strona 38 - 3.0 Start-Up / Commissioning

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.3-6STEP 2 - Press and release the CLOCK bu

Strona 39 - 3.3 Thermostat Programming

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.3.3.2.7 Temperature Override3.3.2.7.1 Temp

Strona 40 - Program Schedule

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.4-14.0 Maintenance4.1 Periodic General M

Strona 41

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.4.1.1.5 Condensate PumpThe optional conden

Strona 42

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.4-3SYMPTOM PROBABLE CAUSE RECOMMENDATIONEv

Strona 43

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.SYMPTOM PROBABLE CAUSE RECOMMENDATIONConde

Strona 44

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.4-5SYMPTOM PROBABLE CAUSE RECOMMENDATIONCo

Strona 45 - 4.0 Maintenance

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.1.0 Introduction1.1 GeneralThank you for

Strona 46

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.4.3 Field ServiceNOTEDo not attempt to ma

Strona 47

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.4-7CAUTION Damage to a replacement compres

Strona 48

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.4-8NOTEDecrease the humidity setpoint belo

Strona 49

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.5-15.0 Product Support GroupSATS provides

Strona 50 - 4.3 Field Service

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.NOTES

Strona 51

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.Appendix A - FormsChecklist for Completed

Strona 52

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.

Strona 53 - 5.0 Product Support Group

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.A-2OHS Series Precision Air Conditioner Te

Strona 54

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.

Strona 55 - Appendix A - Forms

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.Appendix B – GlossaryDefinition of Terms a

Strona 56

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.1-21.4 Product WarrantySATS offers a two

Strona 57

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.OCH0006 REV-

Strona 58

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.1-3Optional Limited Extended Warranty (5

Strona 59 - Appendix B – Glossary

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.1.5 Safety1.5.1 GeneralStulz Air Technol

Strona 60

(©July, 2008)CeilAiR OHS Series Installation, Operation & Maintenance ManualAir Technology Systems, Inc.WARNING This unit employs high voltage equ

Komentarze do niniejszej Instrukcji

Brak uwag